Heynen’s NSG helps our electrical technicians resolve faults safely and effectively

The BPV training location of Enexis in Waalwijk is a source of pride for Rico Schellekens, Senior Technical Specialist and Training Project Leader. This practical training facility is a place where eight electrical technicians can be trained for fault-response duty under the guidance of one experienced instructor. It provides a solution to the acute shortage of qualified fault-response technicians.

“We even won the Enexis HSE Award with it“.

Simulating faults
Rico Schellekens: “In the past, trainee technicians were sent out into the field to learn how to resolve faults there. One trainee paired with one experienced technician. If there were no faults that week, the trainee simply didn’t learn anything about them. The chance of a trainee encountering all types of faults was extremely small. That led to the need to be able to simulate every type of fault in a safe environment. We developed this idea further and even won the Enexis HSE Award with it.”

“NSG, together with a so-called ‘sniffer’ forms the basis for detecting a fault“.

Testing equipment
“In addition to simulating every type of fault, it has also become an ideal location to test the equipment used by our fault-response technicians. For cable fault location, for example, an NSG (automatic intelligent fuse) is always available. Together with a so-called ‘sniffer’ (fault snniffer such as the GS30), this forms the basis for detecting a fault.”

“You wouldn’t believe how many holes we dug unnecessarily.”

NSG automatic intelligent fuse
“The NSG is a clever device,” Rico laughs. “In the past, when there was a fault, we had to get out the maps and start searching and testing more or less blindly. You wouldn’t believe how many holes we dug unnecessarily. Now, when a fault occurs, the first step is to install the NSG in the adjacent electricity cabinet. When this automatic fuse operates, we can immediately read how many meters away the fault is located. A major additional advantage is that residents and businesses quickly have power restored and experience as little disruption as possible.”

“The result is something we are all proud of.”

Development
Jaap Phaff, Account Manager at Heynen: “The NSG is manufactured in Germany by MS-Technik. This automatic intelligent fuse, in its current form, was further developed together with our customer Enexis specifically for the Dutch energy network. This required extensive consultation, collaboration and feedback from all parties involved. The result is something we are all proud of.”

“We focus on keeping the number of outage minutes per household per year as low as possible”.

Enexis
Rico: “As a company, we focus on keeping the number of outage minutes per household per year as low as possible. In the Netherlands, we perform best among all grid operators in this respect, and we intend to keep it that way. In addition, safety is paramount in everything we do. Both the cable fault detection and the cable measurement solutions from Heynen contribute to this.”

“How great would it be if the electricity network became as smart and transparent as a computer network?”

What does the future of Enexis’ fault-response service look like?
“Ideally, in the future every distribution cabinet in every direction will have a kind of NSG, allowing the entire network to be monitored from one central point,” says Rico. “How great would it be if the electricity network became as smart and transparent as a computer network?”

That may still be some way off, but the introduction has already begun with the use of Distribution Automation Light (DALI) and the NSG.

Want to know more?
Are you looking for equipment to test medium- and high-voltage cables, or would you like to learn more about the other solutions Heynen can offer? If so, please contact Jaap Phaff, Account Manager at Heynen Grid Solutions.